Ain-Shams Journal of Anaesthesiology

CASE REPORT
Year
: 2016  |  Volume : 9  |  Issue : 1  |  Page : 126--133

Dexmedetomidine for heart rate control and renal protection in patients undergoing mitral valve replacement for tight mitral stenosis


Salah M Asida1, Hatem S Mohamed2 
1 Assistant Professor of Anaesthesia and Intensive Care, Qena Faculty of Medicine, South Valley University, Egypt
2 Lecturer of Anaesthesia and Intensive Care, Qena Faculty of Medicine, South Valley University, Egypt

Correspondence Address:
Salah M Asida
Assistant Professor of Anaesthesia and Intensive Care, Qena Faculty of Medicine, South Valley University
Egypt

Background Dexmedetomidine (DXM) is an α2 adrenoceptor agonist that reduces the sympathetic outflow from the central nervous system resulting in bradycardia and hypotension. We used this drug in this randomized controlled double-blind study to test its efficacy in controlling the heart rate and its safety regarding renal function in patients undergoing mitral valve replacement surgery. Patients and methods A total of 70 patients scheduled for mitral valve replacement were randomly allocated into two groups: in group D, 35 patients received DXM 1 μg/kg bolus dose over 10 min followed by an infusion of 0.5 μg/kg/h. In group C, 35 patients received saline bolus and infusion by the same method instead of DXM. The heart rate was measured at induction of anesthesia, after the end of bolus infusion, at skin incision, and every 10 min till the start of the cardiopulmonary bypass. We also measured the urine interleukin-18 level during the first 12 h of surgery and serum creatinine and blood urea for 3 days postoperatively. Results The mean heart rate was significantly lower after bolus infusion, at skin incision, at 10 and 30 min, and just before bypass in the DXM group. Also, the urine output was higher in the DXM group during surgery and on the first postoperative day of surgery. No significant difference was found regarding other parameters of renal functions. Conclusion DXM can be used effectively in reducing the heart rate in patients undergoing mitral valve replacement surgery and was associated with an increase in the urinary output, and it did not alter the renal function in this cohort of patients.


How to cite this article:
Asida SM, Mohamed HS. Dexmedetomidine for heart rate control and renal protection in patients undergoing mitral valve replacement for tight mitral stenosis.Ain-Shams J Anaesthesiol 2016;9:126-133


How to cite this URL:
Asida SM, Mohamed HS. Dexmedetomidine for heart rate control and renal protection in patients undergoing mitral valve replacement for tight mitral stenosis. Ain-Shams J Anaesthesiol [serial online] 2016 [cited 2022 May 26 ];9:126-133
Available from: http://www.asja.eg.net/article.asp?issn=1687-7934;year=2016;volume=9;issue=1;spage=126;epage=133;aulast=Asida;type=0